Packet - Telemetry 3
	Timestamp: 2024-10-09 12:26:43
	LSW-UNIDEB:	xx	7 [mV]	2 [mA][4 seconds ago]
	LSW-UNIGYR:	xx	11 [mV]	3 [mA][2 seconds ago]
	LSW-UNISZ2:	xx	0 [mV]	0 [mA][1 seconds ago]
	LSW-UNISZ1:	xx	0 [mV]	0 [mA][25 seconds ago]
	PCU1 LSW status: 0608000C
	PCU2 LSW status: 0608000C
	UNIV-DEB active: 0[INVALID value]
	UNIV-GYR active: 0[INVALID value]
	UNIV-SZ2 active: 0[INVALID value]
	UNIV-SZ1 active: 0[INVALID value]
	MPPT-1 input current: 0 [mA][0 seconds ago]
	MPPT-2 input current: 26 [mA][0 seconds ago]
	MPPT-3 input current: 8 [mA][0 seconds ago]
	MPPT-4 input current: 23 [mA][0 seconds ago]
	MPPT-1 input voltage: 2932 [mV][0 seconds ago]
	MPPT-2 input voltage: 3345 [mV][0 seconds ago]
	MPPT-3 input voltage: 3338 [mV][0 seconds ago]
	MPPT-4 input voltage: 3351 [mV][0 seconds ago]
	MPPT-1 output current: 0 [mA][0 seconds ago]
	MPPT-2 output current: 22 [mA][0 seconds ago]
	MPPT-3 output current: 5 [mA][0 seconds ago]
	MPPT-4 output current: 23 [mA][0 seconds ago]
	MPPT-1 output voltage: 3057 [mV][0 seconds ago]
	MPPT-2 output voltage: 3081 [mV][0 seconds ago]
	MPPT-3 output voltage: 3069 [mV][0 seconds ago]
	MPPT-4 output voltage: 3075 [mV][0 seconds ago]
	SOLAR X- temperature: 0.0 [C][INVALID value]
	SOLAR X+ temperature: 0.0 [C][INVALID value]
	SOLAR Y- temperature: 0.0 [C][INVALID value]
	SOLAR Y+ temperature: 0.0 [C][INVALID value]
	SOLAR Z- temperature: 0.0 [C][INVALID value]
	SOLAR Z+ temperature: 0.0 [C][INVALID value]
	ACCU LIGHTSENSOR X-: 177.000 [lux] (dark mode)[INVALID value]
	ACCU LIGHTSENSOR X+: 177.000 [lux] (dark mode)[INVALID value]
	ACCU LIGHTSENSOR Y-: 177.000 [lux] (dark mode)[INVALID value]
	ACCU LIGHTSENSOR Y+: 177.000 [lux] (dark mode)[INVALID value]
	ACCU LIGHTSENSOR Z-: 177.000 [lux] (dark mode)[INVALID value]
	ACCU LIGHTSENSOR Z+: 177.000 [lux] (dark mode)[INVALID value]
	ACCU INFRASENSOR X-: 65535 [count][INVALID value]
	ACCU INFRASENSOR X+: 65535 [count][INVALID value]
	ACCU INFRASENSOR Y-: 65535 [count][INVALID value]
	ACCU INFRASENSOR Y+: 65535 [count][INVALID value]
	ACCU INFRASENSOR Z-: 65535 [count][INVALID value]
	ACCU INFRASENSOR Z+: 65535 [count][INVALID value]
	Last File-ID: 1
Packet - Telemetry 4
	Timestamp: 2024-10-09 12:26:45
	ACCU1 active: 0[INVALID value]
	ACCU2 active: 0[INVALID value]
	ACCU1 current: 0 [mA][INVALID value]
	ACCU2 current: 0 [mA][INVALID value]
	ACCU1 Temperature X-: 0.0 [C][INVALID value]
	ACCU1 Temperature Y-: 0.0 [C][INVALID value]
	ACCU1 Temperature Y+: 0.0 [C][INVALID value]
	ACCU1 Temperature Z-: 0.0 [C][INVALID value]
	ACCU1 Temperature Z+: 0.0 [C][INVALID value]
	ACCU1 Temperature PANEL: 0.0 [C][INVALID value]
	ACCU1 Temperature REF: 0 [uA][INVALID value]
	ACCU2 Temperature X+: 0.0 [C][INVALID value]
	ACCU2 Temperature Y-: 0.0 [C][INVALID value]
	ACCU2 Temperature Y+: 0.0 [C][INVALID value]
	ACCU2 Temperature Z-: 0.0 [C][INVALID value]
	ACCU2 Temperature Z+: 0.0 [C][INVALID value]
	ACCU2 Temperature PANEL: 0.0 [C][INVALID value]
	ACCU2 Temperature REF: 0 [uA][INVALID value]
	GPS date: 2095-72-96[INVALID value]
	GPS time: 29:49:67.295[INVALID value]
	GPS Latitude: -0.000000 [deg][INVALID value]
	GPS Longitude: -0.000000 [deg][INVALID value]
	GPS Altitude: 4294967295 [m][INVALID value]
	GPS Velocity: 65535 [m/s][INVALID value]
	GPS Course: 6553.500 [deg][INVALID value]
	Gyroscope omega-P: -1 [deg/s][INVALID value]
	Gyroscope omega-R: -1 [deg/s][INVALID value]
	Gyroscope omega-Y: -1 [deg/s][INVALID value]
	Magnetometer X: -1 [nT][INVALID value]
	Magnetometer Y: -1 [nT][INVALID value]
	Magnetometer Z: -1 [nT][INVALID value]
	COM temperature: 409.5 [C][0 seconds ago]
	STX temperature: 0.0 [C][INVALID value]
	RTCC temperature: 5.0 [C][<=5 seconds ago]
Packet - Telemetry 6
	Timestamp: 2024-10-09 12:26:47
	TID1 active: 0[INVALID value]
	TID2 active: 0[INVALID value]
	TID1 temperature: 0.0 [C][INVALID value]
	TID2 temperature: 0.0 [C][INVALID value]
	TID1 voltage: 8191 [mV][INVALID value]
	TID2 voltage: 8191 [mV][INVALID value]
	TID1 measurement serial number: 4294967295[INVALID value]
	TID1 RadFET1: -nan [mGray][INVALID value]
	TID1 RadFET2: -nan [mGray][INVALID value]
	TID2 measurement serial number: 4294967295[INVALID value]
	TID2 RadFET1: -nan [mGray][INVALID value]
	TID2 RadFET2: -nan [mGray][INVALID value]
	COM RX current: 12 [mA][older than 60 seconds]
	COM idle current: 3 [mA][<=60 seconds ago]
	AIS1 buffered messages: 255[INVALID value]
	AIS2 buffered messages: 255[INVALID value]
	HAM repeater enabled: 0[INVALID value]
	ADCS programming enabled: 0[INVALID value]
	ADCS active: 0[INVALID value]
	ADCS exec: 0[INVALID value]
	ADCS erased: 0[INVALID value]
	ADCS valid code: 0[INVALID value]
	ADCS code CRC-16: 0xFFFF[INVALID value]
	ADCS SUN1 status: 0[INVALID value]
	ADCS SUN2 status: 0[INVALID value]
Packet - Beacon
	Timestamp: 2024-10-09 12:26:49
	Serial number -7: 4294967295	RSSI: 255[INVALID value]
	Serial number -6: 4294967295	RSSI: 255[INVALID value]
	Serial number -5: 4294967295	RSSI: 255[INVALID value]
	Serial number -4: 4294967295	RSSI: 255[INVALID value]
	Serial number -3: 4294967295	RSSI: 255[INVALID value]
	Serial number -2: 4294967295	RSSI: 255[INVALID value]
	Serial number -1: 4294967295	RSSI: 255[INVALID value]
	Serial number -0: 4294967295	RSSI: 255[INVALID value]
	COM telemetry TX max current: 57 [mA][older than 60 seconds]
	COM telemetry TX min voltage: 2708 [mV][older than 60 seconds]
	Active COM: COM-2[24 seconds ago]
	Energy management COM TX MCS: G001[0 seconds ago]
	Energy management COM TX power level: 3[0 seconds ago]
	Energy management COM cycle sleep time: 480 [sec][0 seconds ago]
	Energy management emergency mode: ACTIVE[0 seconds ago]
	Message: Hello world! MRC-100 is alive!