Packet - Telemetry 4
	Timestamp: 2024-08-14 11:41:18
	ACCU1 active: 1[99 seconds ago]
	ACCU2 active: 1[99 seconds ago]
	ACCU1 current: -1 [mA][older than 60 seconds]
	ACCU2 current: 0 [mA][older than 60 seconds]
	ACCU1 Temperature X-: 6.5 [C][older than 60 seconds]
	ACCU1 Temperature Y-: 5.5 [C][older than 60 seconds]
	ACCU1 Temperature Y+: 5.1 [C][older than 60 seconds]
	ACCU1 Temperature Z-: 5.2 [C][older than 60 seconds]
	ACCU1 Temperature Z+: 5.6 [C][older than 60 seconds]
	ACCU1 Temperature PANEL: 6.2 [C][older than 60 seconds]
	ACCU1 Temperature REF: 96 [uA][older than 60 seconds]
	ACCU2 Temperature X+: 5.0 [C][older than 60 seconds]
	ACCU2 Temperature Y-: 4.5 [C][older than 60 seconds]
	ACCU2 Temperature Y+: 4.2 [C][older than 60 seconds]
	ACCU2 Temperature Z-: 3.6 [C][older than 60 seconds]
	ACCU2 Temperature Z+: 4.4 [C][older than 60 seconds]
	ACCU2 Temperature PANEL: 4.8 [C][older than 60 seconds]
	ACCU2 Temperature REF: 96 [uA][older than 60 seconds]
	GPS date: 2095-72-96[INVALID value]
	GPS time: 29:49:67.295[INVALID value]
	GPS Latitude: -0.000000 [deg][INVALID value]
	GPS Longitude: -0.000000 [deg][INVALID value]
	GPS Altitude: 4294967295 [m][INVALID value]
	GPS Velocity: 65535 [m/s][INVALID value]
	GPS Course: 6553.500 [deg][INVALID value]
	Gyroscope omega-P: 0 [deg/s][99 seconds ago]
	Gyroscope omega-R: -1 [deg/s][99 seconds ago]
	Gyroscope omega-Y: 0 [deg/s][99 seconds ago]
	Magnetometer X: -20135 [nT][99 seconds ago]
	Magnetometer Y: 18701 [nT][99 seconds ago]
	Magnetometer Z: -31149 [nT][99 seconds ago]
	COM temperature: 409.5 [C][0 seconds ago]
	STX temperature: 0.0 [C][INVALID value]
	RTCC temperature: 15.0 [C][<=5 seconds ago]
Packet - Telemetry 6
	Timestamp: 2024-08-14 11:41:20
	TID1 active: 1[older than 125 seconds]
	TID2 active: 1[older than 125 seconds]
	TID1 temperature: -5.1 [C][older than 60 seconds]
	TID2 temperature: -2.7 [C][older than 60 seconds]
	TID1 voltage: 2971 [mV][older than 60 seconds]
	TID2 voltage: 2946 [mV][older than 60 seconds]
	TID1 measurement serial number: 1[older than 125 seconds]
	TID1 RadFET1: 9.754247 [mGray][older than 125 seconds]
	TID1 RadFET2: 9.558766 [mGray][older than 125 seconds]
	TID2 measurement serial number: 1[older than 125 seconds]
	TID2 RadFET1: 6.779092 [mGray][older than 125 seconds]
	TID2 RadFET2: 7.009010 [mGray][older than 125 seconds]
	COM RX current: 12 [mA][older than 60 seconds]
	COM idle current: 7 [mA][<=60 seconds ago]
	AIS1 buffered messages: 255[INVALID value]
	AIS2 buffered messages: 255[INVALID value]
	HAM repeater enabled: 0[INVALID value]
	ADCS programming enabled: 0[INVALID value]
	ADCS active: 0[INVALID value]
	ADCS exec: 0[INVALID value]
	ADCS erased: 0[INVALID value]
	ADCS valid code: 0[INVALID value]
	ADCS code CRC-16: 0xFFFF[INVALID value]
	ADCS SUN1 status: 0[INVALID value]
	ADCS SUN2 status: 0[INVALID value]
Packet - Beacon
	Timestamp: 2024-08-14 11:41:22
	Serial number -7: 4294967295	RSSI: 255[INVALID value]
	Serial number -6: 4294967295	RSSI: 255[INVALID value]
	Serial number -5: 4294967295	RSSI: 255[INVALID value]
	Serial number -4: 4294967295	RSSI: 255[INVALID value]
	Serial number -3: 4294967295	RSSI: 255[INVALID value]
	Serial number -2: 4294967295	RSSI: 255[INVALID value]
	Serial number -1: 4294967295	RSSI: 255[INVALID value]
	Serial number -0: 4294967295	RSSI: 255[INVALID value]
	COM telemetry TX max current: 58 [mA][older than 60 seconds]
	COM telemetry TX min voltage: 2815 [mV][older than 60 seconds]
	Active COM: COM-2[24 seconds ago]
	Energy management COM TX MCS: G001[0 seconds ago]
	Energy management COM TX power level: 3[0 seconds ago]
	Energy management COM cycle sleep time: 480 [sec][0 seconds ago]
	Energy management emergency mode: ACTIVE[0 seconds ago]
	Message: Hello world! MRC-100 is alive!