Packet - Telemetry 4
	Timestamp: 2024-04-19 12:07:34
	ACCU1 active: 1[older than 125 seconds]
	ACCU2 active: 1[older than 125 seconds]
	ACCU1 current: -22 [mA][older than 60 seconds]
	ACCU2 current: -27 [mA][older than 60 seconds]
	ACCU1 Temperature X-: 7.4 [C][older than 60 seconds]
	ACCU1 Temperature Y-: 7.3 [C][older than 60 seconds]
	ACCU1 Temperature Y+: 6.9 [C][older than 60 seconds]
	ACCU1 Temperature Z-: 6.3 [C][older than 60 seconds]
	ACCU1 Temperature Z+: 7.1 [C][older than 60 seconds]
	ACCU1 Temperature PANEL: 6.0 [C][older than 60 seconds]
	ACCU1 Temperature REF: 95 [uA][older than 60 seconds]
	ACCU2 Temperature X+: 7.9 [C][older than 60 seconds]
	ACCU2 Temperature Y-: 7.1 [C][older than 60 seconds]
	ACCU2 Temperature Y+: 7.0 [C][older than 60 seconds]
	ACCU2 Temperature Z-: 6.4 [C][older than 60 seconds]
	ACCU2 Temperature Z+: 7.3 [C][older than 60 seconds]
	ACCU2 Temperature PANEL: 6.2 [C][older than 60 seconds]
	ACCU2 Temperature REF: 95 [uA][older than 60 seconds]
	GPS date: 2095-72-96[INVALID value]
	GPS time: 29:49:67.295[INVALID value]
	GPS Latitude: -0.000000 [deg][INVALID value]
	GPS Longitude: -0.000000 [deg][INVALID value]
	GPS Altitude: 4294967295 [m][INVALID value]
	GPS Velocity: 65535 [m/s][INVALID value]
	GPS Course: 6553.500 [deg][INVALID value]
	Gyroscope omega-P: 0 [deg/s][older than 125 seconds]
	Gyroscope omega-R: 0 [deg/s][older than 125 seconds]
	Gyroscope omega-Y: 0 [deg/s][older than 125 seconds]
	Magnetometer X: -17038 [nT][older than 125 seconds]
	Magnetometer Y: 20883 [nT][older than 125 seconds]
	Magnetometer Z: -29099 [nT][older than 125 seconds]
	COM temperature: -10.4 [C][0 seconds ago]
	STX temperature: 0.0 [C][INVALID value]
	RTCC temperature: 15.0 [C][1 seconds ago]
Packet - Telemetry 6
	Timestamp: 2024-04-19 12:07:34
	TID1 active: 1[38 seconds ago]
	TID2 active: 1[38 seconds ago]
	TID1 temperature: 2.5 [C][<=60 seconds ago]
	TID2 temperature: 3.1 [C][<=60 seconds ago]
	TID1 voltage: 3322 [mV][<=60 seconds ago]
	TID2 voltage: 3302 [mV][<=60 seconds ago]
	TID1 measurement serial number: 8[38 seconds ago]
	TID1 RadFET1: 8.400303 [mGray][38 seconds ago]
	TID1 RadFET2: 8.186676 [mGray][38 seconds ago]
	TID2 measurement serial number: 8[38 seconds ago]
	TID2 RadFET1: 5.265818 [mGray][38 seconds ago]
	TID2 RadFET2: 5.471891 [mGray][38 seconds ago]
	COM RX current: 14 [mA][<=60 seconds ago]
	COM idle current: 21 [mA][<=20 seconds ago]
	AIS1 buffered messages: 255[INVALID value]
	AIS2 buffered messages: 255[INVALID value]
	HAM repeater enabled: 0[INVALID value]
	ADCS programming enabled: 0[INVALID value]
	ADCS active: 0[INVALID value]
	ADCS exec: 0[INVALID value]
	ADCS erased: 0[INVALID value]
	ADCS valid code: 0[INVALID value]
	ADCS code CRC-16: 0xFFFF[INVALID value]
	ADCS SUN1 status: 0[INVALID value]
	ADCS SUN2 status: 0[INVALID value]
Packet - Beacon
	Timestamp: 2024-04-19 12:07:34
	Serial number -7: 1712921568	RSSI: 168[older than 125 seconds]
	Serial number -6: 1713006678	RSSI: 170[older than 125 seconds]
	Serial number -5: 1713091808	RSSI: 162[older than 125 seconds]
	Serial number -4: 1713182365	RSSI: 167[older than 125 seconds]
	Serial number -3: 1713267509	RSSI: 169[older than 125 seconds]
	Serial number -2: 1713352520	RSSI: 170[older than 125 seconds]
	Serial number -1: 1713437617	RSSI: 162[older than 125 seconds]
	Serial number -0: 1713522860	RSSI: 164[older than 125 seconds]
	COM telemetry TX max current: 112 [mA][<=60 seconds ago]
	COM telemetry TX min voltage: 3237 [mV][<=60 seconds ago]
	Active COM: COM-2[17 seconds ago]
	Energy management COM TX MCS: G012[0 seconds ago]
	Energy management COM TX power level: 15[0 seconds ago]
	Energy management COM cycle sleep time: 26 [sec][0 seconds ago]
	Energy management emergency mode: inactive[0 seconds ago]
	Message: Hello world! MRC-100 is alive!