Packet - Telemetry 3
	Timestamp: 2024-01-26 10:52:51
	LSW-UNIDEB:	xx	7 [mV]	4 [mA][15 seconds ago]
	LSW-UNIGYR:	xx	11 [mV]	5 [mA][13 seconds ago]
	LSW-UNISZ2:	xx	0 [mV]	0 [mA][12 seconds ago]
	LSW-UNISZ1:	xx	0 [mV]	0 [mA][10 seconds ago]
	PCU1 LSW status: 060930CC
	PCU2 LSW status: 060930CC
	UNIV-DEB active: 0[INVALID value]
	UNIV-GYR active: 0[INVALID value]
	UNIV-SZ2 active: 0[INVALID value]
	UNIV-SZ1 active: 0[INVALID value]
	MPPT-1 input current: 177 [mA][1 seconds ago]
	MPPT-2 input current: 0 [mA][<=60 seconds ago]
	MPPT-3 input current: 26 [mA][0 seconds ago]
	MPPT-4 input current: 0 [mA][0 seconds ago]
	MPPT-1 input voltage: 3912 [mV][1 seconds ago]
	MPPT-2 input voltage: 2964 [mV][<=60 seconds ago]
	MPPT-3 input voltage: 3841 [mV][0 seconds ago]
	MPPT-4 input voltage: 3673 [mV][0 seconds ago]
	MPPT-1 output current: 168 [mA][1 seconds ago]
	MPPT-2 output current: 0 [mA][<=60 seconds ago]
	MPPT-3 output current: 24 [mA][0 seconds ago]
	MPPT-4 output current: 0 [mA][0 seconds ago]
	MPPT-1 output voltage: 3524 [mV][1 seconds ago]
	MPPT-2 output voltage: 3506 [mV][<=60 seconds ago]
	MPPT-3 output voltage: 3536 [mV][0 seconds ago]
	MPPT-4 output voltage: 3518 [mV][0 seconds ago]
	SOLAR X- temperature: -44.9 [C][older than 60 seconds]
	SOLAR X+ temperature: -44.9 [C][older than 60 seconds]
	SOLAR Y- temperature: 17.9 [C][older than 60 seconds]
	SOLAR Y+ temperature: -44.9 [C][older than 60 seconds]
	SOLAR Z- temperature: -44.9 [C][older than 60 seconds]
	SOLAR Z+ temperature: -44.9 [C][older than 60 seconds]
	ACCU LIGHTSENSOR X-: 12076.886 [lux] (light mode)[older than 125 seconds]
	ACCU LIGHTSENSOR X+: 82890.349 [lux] (light mode)[older than 125 seconds]
	ACCU LIGHTSENSOR Y-: 1282.893 [lux] (light mode)[older than 125 seconds]
	ACCU LIGHTSENSOR Y+: 17844.373 [lux] (light mode)[older than 125 seconds]
	ACCU LIGHTSENSOR Z-: 81325.442 [lux] (light mode)[older than 125 seconds]
	ACCU LIGHTSENSOR Z+: 17982.616 [lux] (light mode)[older than 125 seconds]
	ACCU INFRASENSOR X-: 1114 [count][older than 125 seconds]
	ACCU INFRASENSOR X+: 6340 [count][older than 125 seconds]
	ACCU INFRASENSOR Y-: 111 [count][older than 125 seconds]
	ACCU INFRASENSOR Y+: 1528 [count][older than 125 seconds]
	ACCU INFRASENSOR Z-: 8024 [count][older than 125 seconds]
	ACCU INFRASENSOR Z+: 1805 [count][older than 125 seconds]
	Last File-ID: 356
Packet - Telemetry 4
	Timestamp: 2024-01-26 10:52:52
	ACCU1 active: 1[older than 125 seconds]
	ACCU2 active: 1[older than 125 seconds]
	ACCU1 current: -47 [mA][older than 60 seconds]
	ACCU2 current: 39 [mA][older than 60 seconds]
	ACCU1 Temperature X-: 13.2 [C][older than 60 seconds]
	ACCU1 Temperature Y-: 11.3 [C][older than 60 seconds]
	ACCU1 Temperature Y+: 10.6 [C][older than 60 seconds]
	ACCU1 Temperature Z-: 11.6 [C][older than 60 seconds]
	ACCU1 Temperature Z+: 11.8 [C][older than 60 seconds]
	ACCU1 Temperature PANEL: 15.0 [C][older than 60 seconds]
	ACCU1 Temperature REF: 95 [uA][older than 60 seconds]
	ACCU2 Temperature X+: 5.3 [C][older than 60 seconds]
	ACCU2 Temperature Y-: 5.7 [C][older than 60 seconds]
	ACCU2 Temperature Y+: 3.5 [C][older than 60 seconds]
	ACCU2 Temperature Z-: 1.6 [C][older than 60 seconds]
	ACCU2 Temperature Z+: 5.1 [C][older than 60 seconds]
	ACCU2 Temperature PANEL: 4.3 [C][older than 60 seconds]
	ACCU2 Temperature REF: 92 [uA][older than 60 seconds]
	GPS date: 2095-72-96[INVALID value]
	GPS time: 29:49:67.295[INVALID value]
	GPS Latitude: -0.000000 [deg][INVALID value]
	GPS Longitude: -0.000000 [deg][INVALID value]
	GPS Altitude: 4294967295 [m][INVALID value]
	GPS Velocity: 65535 [m/s][INVALID value]
	GPS Course: 6553.500 [deg][INVALID value]
	Gyroscope omega-P: 0 [deg/s][older than 125 seconds]
	Gyroscope omega-R: -1 [deg/s][older than 125 seconds]
	Gyroscope omega-Y: 0 [deg/s][older than 125 seconds]
	Magnetometer X: -20023 [nT][older than 125 seconds]
	Magnetometer Y: -26340 [nT][older than 125 seconds]
	Magnetometer Z: 12445 [nT][older than 125 seconds]
	COM temperature: -26.3 [C][0 seconds ago]
	STX temperature: 0.0 [C][INVALID value]
	RTCC temperature: 7.0 [C][<=5 seconds ago]
Packet - Telemetry 6
	Timestamp: 2024-01-26 10:52:52
	TID1 active: 1[60 seconds ago]
	TID2 active: 1[60 seconds ago]
	TID1 temperature: -2.6 [C][<=60 seconds ago]
	TID2 temperature: -1.2 [C][<=60 seconds ago]
	TID1 voltage: 3377 [mV][<=60 seconds ago]
	TID2 voltage: 3345 [mV][<=60 seconds ago]
	TID1 measurement serial number: 16[60 seconds ago]
	TID1 RadFET1: 7.295744 [mGray][60 seconds ago]
	TID1 RadFET2: 7.111654 [mGray][60 seconds ago]
	TID2 measurement serial number: 16[60 seconds ago]
	TID2 RadFET1: 4.196652 [mGray][60 seconds ago]
	TID2 RadFET2: 4.393518 [mGray][60 seconds ago]
	COM RX current: 13 [mA][<=20 seconds ago]
	COM idle current: 10 [mA][<=60 seconds ago]
	AIS1 buffered messages: 255[INVALID value]
	AIS2 buffered messages: 255[INVALID value]
	HAM repeater enabled: 0[INVALID value]
	ADCS programming enabled: 0[INVALID value]
	ADCS active: 0[INVALID value]
	ADCS exec: 0[INVALID value]
	ADCS erased: 0[INVALID value]
	ADCS valid code: 0[INVALID value]
	ADCS code CRC-16: 0xFFFF[INVALID value]
	ADCS SUN1 status: 0[INVALID value]
	ADCS SUN2 status: 0[INVALID value]
Packet - Telemetry 1
	Timestamp: 2024-01-26 10:53:25
	Uptime: 1035863
	OBC-ID: 1
	Osc status: 1
	PCU1 active: 1[0 seconds ago]
	PCU2 active: 1[1 seconds ago]
	PCU DSW1 satus: 1[2 seconds ago]
	PCU DSW2 satus: 1[2 seconds ago]
	PCU RBF satus: 1[2 seconds ago]
	PCU Antenna Deployment flag: 1[2 seconds ago]
	PCU Antenna Deployment status: 1[2 seconds ago]
	Antenna opened condition: 09E2[6 seconds ago]
	PCU1 boot counter: 819[2 seconds ago]
	PCU2 boot counter: 822[2 seconds ago]
	PCU1 uptime: 16820 [minutes][2 seconds ago]
	PCU2 uptime: 16794 [minutes][2 seconds ago]
	PCU unregulated bus voltage: 3604 [mV][1 seconds ago]
	PCU regulated bus voltage: 3376 [mV][1 seconds ago]
	PCU temperature: -10.5 [C][1 seconds ago]
	PCU supply voltage: 3359 [mV][1 seconds ago]
	SDC1 input current: 54 [mA][1 seconds ago]
	SDC1 output current: 59 [mA][<=5 seconds ago]
	SDC1 output voltage: 3563 [mV][<=5 seconds ago]
	SDC2 input current: 492 [mA][1 seconds ago]
	SDC2 output current: 118 [mA][1 seconds ago]
	SDC2 output voltage: 635 [mV][1 seconds ago]
	SDC1 overcurrent status: 0[1 seconds ago]
	SDC2 overcurrent status: 0[1 seconds ago]
	SDC1 overvoltage status: 0[1 seconds ago]
	SDC2 overvoltage status: 0[1 seconds ago]
	LSW-PCU1 flag: On[1 seconds ago]
	LSW-PCU2 flag: On[1 seconds ago]
	LSW-SDC1 flag: On[1 seconds ago]
	LSW-SDC2 flag: OFF[1 seconds ago]
	LSW-OBC1 flag: OFF[1 seconds ago]
	LSW-OBC2 flag: On[1 seconds ago]
	LSW-SPA2 flag: OFF[1 seconds ago]
	LSW-SPA1 flag: OFF[1 seconds ago]
	LSW-COM1 flag: OFF[1 seconds ago]
	LSW-COM2 flag: On[1 seconds ago]
	LSW-ADC1 flag: OFF[1 seconds ago]
	LSW-ADC2 flag: OFF[1 seconds ago]
	LSW-ACCU1 flag: OFF[1 seconds ago]
	LSW-ACCU2 flag: OFF[1 seconds ago]
	LSW-SUN1 flag: OFF[1 seconds ago]
	LSW-SUN2 flag: OFF[1 seconds ago]
	LSW-STX1 flag: OFF[1 seconds ago]
	LSW-STX2 flag: OFF[1 seconds ago]
	LSW-TID1 flag: On[1 seconds ago]
	LSW-TID2 flag: On[0 seconds ago]
	LSW-AIS1 flag: OFF[1 seconds ago]
	LSW-AIS2 flag: OFF[1 seconds ago]
	LSW-GPSCAM1 flag: OFF[1 seconds ago]
	LSW-GPSCAM2 flag: OFF[1 seconds ago]
	LSW-PASSIVE1 flag: OFF[1 seconds ago]
	LSW-PASSIVE2 flag: OFF[1 seconds ago]
	LSW-UNIDEB flag: OFF[1 seconds ago]
	LSW-UNIGYR flag: OFF[1 seconds ago]
	LSW-(null) flag: FAIL[18 seconds ago]
	LSW-UNISZ2 flag: OFF[1 seconds ago]
	LSW-UNISZ1 flag: OFF[1 seconds ago]
	LSW-MPPT12 flag: OFF[1 seconds ago]
	LSW-MPPT34 flag: OFF[1 seconds ago]
	UART2 error: 0x00[older than 125 seconds]
	UART3 error: 0x00[1 seconds ago]
	UART4 error: 0x00[0 seconds ago]
	UART6 error: 0x00[0 seconds ago]
	UART error rate / COM & STX: 0%[109 seconds ago]
	UART error rate / PCU1: 0%[40 seconds ago]
	UART error rate / PCU2: 0%[32 seconds ago]
	UART error rate / MPPT: 30%[4 seconds ago]
	UART error rate / HiBUS: 20%[older than 125 seconds]
	UART error rate / SPA1: 100%[INVALID value]
	UART error rate / SPA2: 100%[INVALID value]
	UART error rate / LoBUS: 100%[INVALID value]
	UART error rate / ADCS: 100%[93 seconds ago]
	UART error rate / ACCU: 100%[4 seconds ago]
Packet - Telemetry 2
	Timestamp: 2024-01-26 10:53:25
	LSW-PCU1:	ON	3532 [mV]	4 [mA][<=60 seconds ago]
	LSW-PCU2:	ON	3546 [mV]	2 [mA][13 seconds ago]
	LSW-SDC1:	ON	3554 [mV]	42 [mA][13 seconds ago]
	LSW-SDC2:	xx	628 [mV]	490 [mA][12 seconds ago]
	LSW-OBC1:	xx	0 [mV]	0 [mA][11 seconds ago]
	LSW-OBC2:	ON	3329 [mV]	20 [mA][11 seconds ago]
	LSW-SPA2:	xx	0 [mV]	0 [mA][9 seconds ago]
	LSW-SPA1:	xx	0 [mV]	0 [mA][9 seconds ago]
	LSW-COM1:	xx	22 [mV]	9 [mA][9 seconds ago]
	LSW-COM2:	ON	3377 [mV]	7 [mA][7 seconds ago]
	LSW-ADC1:	xx	14 [mV]	11 [mA][7 seconds ago]
	LSW-ADC2:	xx	410 [mV]	320 [mA][7 seconds ago]
	LSW-ACCU1:	xx	25 [mV]	11 [mA][5 seconds ago]
	LSW-ACCU2:	xx	33 [mV]	11 [mA][5 seconds ago]
	LSW-SUN1:	xx	0 [mV]	0 [mA][4 seconds ago]
	LSW-SUN2:	xx	3 [mV]	2 [mA][3 seconds ago]
	LSW-STX1:	xx	22 [mV]	17 [mA][2 seconds ago]
	LSW-STX2:	xx	25 [mV]	20 [mA][2 seconds ago]
	LSW-TID1:	ON	3355 [mV]	2 [mA][1 seconds ago]
	LSW-TID2:	ON	3307 [mV]	0 [mA][0 seconds ago]
	LSW-AIS1:	xx	0 [mV]	0 [mA][<=30 seconds ago]
	LSW-AIS2:	xx	11 [mV]	4 [mA][25 seconds ago]
	LSW-GPSCAM1:	xx	29 [mV]	11 [mA][25 seconds ago]
	LSW-GPSCAM2:	xx	25 [mV]	11 [mA][24 seconds ago]
	LSW-PASSIVE1:	xx	29 [mV]	9 [mA][23 seconds ago]
	LSW-PASSIVE2:	ON	3303 [mV]	8 [mA][22 seconds ago]
	LSW-MPPT12:	xx	938 [mV]	466 [mA][15 seconds ago]
	LSW-MPPT34:	xx	960 [mV]	474 [mA][15 seconds ago]
Packet - Telemetry 3
	Timestamp: 2024-01-26 10:53:25
	LSW-UNIDEB:	xx	11 [mV]	3 [mA][22 seconds ago]
	LSW-UNIGYR:	xx	14 [mV]	5 [mA][19 seconds ago]
	LSW-UNISZ2:	xx	0 [mV]	0 [mA][18 seconds ago]
	LSW-UNISZ1:	xx	0 [mV]	0 [mA][16 seconds ago]
	PCU1 LSW status: 060930CC
	PCU2 LSW status: 060930CC
	UNIV-DEB active: 0[INVALID value]
	UNIV-GYR active: 0[INVALID value]
	UNIV-SZ2 active: 0[INVALID value]
	UNIV-SZ1 active: 0[INVALID value]
	MPPT-1 input current: 61 [mA][0 seconds ago]
	MPPT-2 input current: 180 [mA][0 seconds ago]
	MPPT-3 input current: 1 [mA][1 seconds ago]
	MPPT-4 input current: 0 [mA][1 seconds ago]
	MPPT-1 input voltage: 3886 [mV][0 seconds ago]
	MPPT-2 input voltage: 3860 [mV][0 seconds ago]
	MPPT-3 input voltage: 3802 [mV][1 seconds ago]
	MPPT-4 input voltage: 3564 [mV][1 seconds ago]
	MPPT-1 output current: 57 [mA][0 seconds ago]
	MPPT-2 output current: 169 [mA][0 seconds ago]
	MPPT-3 output current: 1 [mA][1 seconds ago]
	MPPT-4 output current: 0 [mA][1 seconds ago]
	MPPT-1 output voltage: 3530 [mV][0 seconds ago]
	MPPT-2 output voltage: 3536 [mV][0 seconds ago]
	MPPT-3 output voltage: 3554 [mV][1 seconds ago]
	MPPT-4 output voltage: 3542 [mV][1 seconds ago]
	SOLAR X- temperature: -44.9 [C][older than 60 seconds]
	SOLAR X+ temperature: -44.9 [C][older than 60 seconds]
	SOLAR Y- temperature: 17.9 [C][older than 60 seconds]
	SOLAR Y+ temperature: -44.9 [C][older than 60 seconds]
	SOLAR Z- temperature: -44.9 [C][older than 60 seconds]
	SOLAR Z+ temperature: -44.9 [C][older than 60 seconds]
	ACCU LIGHTSENSOR X-: 12076.886 [lux] (light mode)[older than 125 seconds]
	ACCU LIGHTSENSOR X+: 82890.349 [lux] (light mode)[older than 125 seconds]
	ACCU LIGHTSENSOR Y-: 1282.893 [lux] (light mode)[older than 125 seconds]
	ACCU LIGHTSENSOR Y+: 17844.373 [lux] (light mode)[older than 125 seconds]
	ACCU LIGHTSENSOR Z-: 81325.442 [lux] (light mode)[older than 125 seconds]
	ACCU LIGHTSENSOR Z+: 17982.616 [lux] (light mode)[older than 125 seconds]
	ACCU INFRASENSOR X-: 1114 [count][older than 125 seconds]
	ACCU INFRASENSOR X+: 6340 [count][older than 125 seconds]
	ACCU INFRASENSOR Y-: 111 [count][older than 125 seconds]
	ACCU INFRASENSOR Y+: 1528 [count][older than 125 seconds]
	ACCU INFRASENSOR Z-: 8024 [count][older than 125 seconds]
	ACCU INFRASENSOR Z+: 1805 [count][older than 125 seconds]
	Last File-ID: 356
Packet - Telemetry 6
	Timestamp: 2024-01-26 10:53:26
	TID1 active: 1[94 seconds ago]
	TID2 active: 1[33 seconds ago]
	TID1 temperature: -2.6 [C][older than 60 seconds]
	TID2 temperature: -0.5 [C][<=60 seconds ago]
	TID1 voltage: 3377 [mV][older than 60 seconds]
	TID2 voltage: 3330 [mV][<=60 seconds ago]
	TID1 measurement serial number: 16[94 seconds ago]
	TID1 RadFET1: 7.295744 [mGray][94 seconds ago]
	TID1 RadFET2: 7.111654 [mGray][94 seconds ago]
	TID2 measurement serial number: 18[33 seconds ago]
	TID2 RadFET1: 4.196652 [mGray][33 seconds ago]
	TID2 RadFET2: 4.393518 [mGray][33 seconds ago]
	COM RX current: 14 [mA][<=60 seconds ago]
	COM idle current: 10 [mA][older than 60 seconds]
	AIS1 buffered messages: 255[INVALID value]
	AIS2 buffered messages: 255[INVALID value]
	HAM repeater enabled: 0[INVALID value]
	ADCS programming enabled: 0[INVALID value]
	ADCS active: 0[INVALID value]
	ADCS exec: 0[INVALID value]
	ADCS erased: 0[INVALID value]
	ADCS valid code: 0[INVALID value]
	ADCS code CRC-16: 0xFFFF[INVALID value]
	ADCS SUN1 status: 0[INVALID value]
	ADCS SUN2 status: 0[INVALID value]
Packet - Telemetry 2
	Timestamp: 2024-01-26 10:54:23
	LSW-PCU1:	ON	3524 [mV]	4 [mA][19 seconds ago]
	LSW-PCU2:	ON	3554 [mV]	2 [mA][19 seconds ago]
	LSW-SDC1:	ON	3568 [mV]	80 [mA][19 seconds ago]
	LSW-SDC2:	xx	628 [mV]	498 [mA][17 seconds ago]
	LSW-OBC1:	xx	0 [mV]	0 [mA][17 seconds ago]
	LSW-OBC2:	ON	3329 [mV]	36 [mA][16 seconds ago]
	LSW-SPA2:	xx	0 [mV]	0 [mA][14 seconds ago]
	LSW-SPA1:	xx	0 [mV]	0 [mA][13 seconds ago]
	LSW-COM1:	xx	22 [mV]	10 [mA][13 seconds ago]
	LSW-COM2:	ON	3370 [mV]	6 [mA][11 seconds ago]
	LSW-ADC1:	xx	11 [mV]	11 [mA][11 seconds ago]
	LSW-ADC2:	xx	413 [mV]	323 [mA][11 seconds ago]
	LSW-ACCU1:	xx	25 [mV]	11 [mA][9 seconds ago]
	LSW-ACCU2:	xx	25 [mV]	11 [mA][9 seconds ago]
	LSW-SUN1:	xx	0 [mV]	0 [mA][9 seconds ago]
	LSW-SUN2:	xx	3 [mV]	2 [mA][7 seconds ago]
	LSW-STX1:	xx	18 [mV]	16 [mA][7 seconds ago]
	LSW-STX2:	xx	22 [mV]	19 [mA][7 seconds ago]
	LSW-TID1:	ON	3344 [mV]	2 [mA][5 seconds ago]
	LSW-TID2:	ON	3351 [mV]	0 [mA][5 seconds ago]
	LSW-AIS1:	xx	0 [mV]	0 [mA][4 seconds ago]
	LSW-AIS2:	xx	11 [mV]	4 [mA][3 seconds ago]
	LSW-GPSCAM1:	xx	33 [mV]	14 [mA][2 seconds ago]
	LSW-GPSCAM2:	xx	36 [mV]	14 [mA][2 seconds ago]
	LSW-PASSIVE1:	xx	33 [mV]	11 [mA][0 seconds ago]
	LSW-PASSIVE2:	xx	3 [mV]	2 [mA][0 seconds ago]
	LSW-MPPT12:	xx	952 [mV]	470 [mA][21 seconds ago]
	LSW-MPPT34:	xx	968 [mV]	476 [mA][21 seconds ago]
Packet - Telemetry 3
	Timestamp: 2024-01-26 10:54:24
	LSW-UNIDEB:	xx	11 [mV]	4 [mA][1 seconds ago]
	LSW-UNIGYR:	xx	14 [mV]	6 [mA][25 seconds ago]
	LSW-UNISZ2:	xx	0 [mV]	0 [mA][24 seconds ago]
	LSW-UNISZ1:	xx	0 [mV]	0 [mA][22 seconds ago]
	PCU1 LSW status: 060930CC
	PCU2 LSW status: 060930CC
	UNIV-DEB active: 0[INVALID value]
	UNIV-GYR active: 0[INVALID value]
	UNIV-SZ2 active: 0[INVALID value]
	UNIV-SZ1 active: 0[INVALID value]
	MPPT-1 input current: 39 [mA][1 seconds ago]
	MPPT-2 input current: 107 [mA][1 seconds ago]
	MPPT-3 input current: 6 [mA][0 seconds ago]
	MPPT-4 input current: 27 [mA][1 seconds ago]
	MPPT-1 input voltage: 3822 [mV][1 seconds ago]
	MPPT-2 input voltage: 3834 [mV][1 seconds ago]
	MPPT-3 input voltage: 3751 [mV][0 seconds ago]
	MPPT-4 input voltage: 3815 [mV][1 seconds ago]
	MPPT-1 output current: 35 [mA][1 seconds ago]
	MPPT-2 output current: 98 [mA][1 seconds ago]
	MPPT-3 output current: 4 [mA][0 seconds ago]
	MPPT-4 output current: 27 [mA][1 seconds ago]
	MPPT-1 output voltage: 3483 [mV][1 seconds ago]
	MPPT-2 output voltage: 3530 [mV][1 seconds ago]
	MPPT-3 output voltage: 3489 [mV][0 seconds ago]
	MPPT-4 output voltage: 3530 [mV][1 seconds ago]
	SOLAR X- temperature: -44.9 [C][older than 60 seconds]
	SOLAR X+ temperature: -44.9 [C][older than 60 seconds]
	SOLAR Y- temperature: 17.9 [C][older than 60 seconds]
	SOLAR Y+ temperature: -44.9 [C][older than 60 seconds]
	SOLAR Z- temperature: -44.9 [C][older than 60 seconds]
	SOLAR Z+ temperature: -44.9 [C][older than 60 seconds]
	ACCU LIGHTSENSOR X-: 12076.886 [lux] (light mode)[older than 125 seconds]
	ACCU LIGHTSENSOR X+: 82890.349 [lux] (light mode)[older than 125 seconds]
	ACCU LIGHTSENSOR Y-: 1282.893 [lux] (light mode)[older than 125 seconds]
	ACCU LIGHTSENSOR Y+: 17844.373 [lux] (light mode)[older than 125 seconds]
	ACCU LIGHTSENSOR Z-: 81325.442 [lux] (light mode)[older than 125 seconds]
	ACCU LIGHTSENSOR Z+: 17982.616 [lux] (light mode)[older than 125 seconds]
	ACCU INFRASENSOR X-: 1114 [count][older than 125 seconds]
	ACCU INFRASENSOR X+: 6340 [count][older than 125 seconds]
	ACCU INFRASENSOR Y-: 111 [count][older than 125 seconds]
	ACCU INFRASENSOR Y+: 1528 [count][older than 125 seconds]
	ACCU INFRASENSOR Z-: 8024 [count][older than 125 seconds]
	ACCU INFRASENSOR Z+: 1805 [count][older than 125 seconds]
	Last File-ID: 356
Packet - Telemetry 4
	Timestamp: 2024-01-26 10:54:24
	ACCU1 active: 1[older than 125 seconds]
	ACCU2 active: 1[older than 125 seconds]
	ACCU1 current: -47 [mA][older than 60 seconds]
	ACCU2 current: 39 [mA][older than 60 seconds]
	ACCU1 Temperature X-: 13.2 [C][older than 60 seconds]
	ACCU1 Temperature Y-: 11.3 [C][older than 60 seconds]
	ACCU1 Temperature Y+: 10.6 [C][older than 60 seconds]
	ACCU1 Temperature Z-: 11.6 [C][older than 60 seconds]
	ACCU1 Temperature Z+: 11.8 [C][older than 60 seconds]
	ACCU1 Temperature PANEL: 15.0 [C][older than 60 seconds]
	ACCU1 Temperature REF: 95 [uA][older than 60 seconds]
	ACCU2 Temperature X+: 5.3 [C][older than 60 seconds]
	ACCU2 Temperature Y-: 5.7 [C][older than 60 seconds]
	ACCU2 Temperature Y+: 3.5 [C][older than 60 seconds]
	ACCU2 Temperature Z-: 1.6 [C][older than 60 seconds]
	ACCU2 Temperature Z+: 5.1 [C][older than 60 seconds]
	ACCU2 Temperature PANEL: 4.3 [C][older than 60 seconds]
	ACCU2 Temperature REF: 92 [uA][older than 60 seconds]
	GPS date: 2095-72-96[INVALID value]
	GPS time: 29:49:67.295[INVALID value]
	GPS Latitude: -0.000000 [deg][INVALID value]
	GPS Longitude: -0.000000 [deg][INVALID value]
	GPS Altitude: 4294967295 [m][INVALID value]
	GPS Velocity: 65535 [m/s][INVALID value]
	GPS Course: 6553.500 [deg][INVALID value]
	Gyroscope omega-P: 0 [deg/s][older than 125 seconds]
	Gyroscope omega-R: -1 [deg/s][older than 125 seconds]
	Gyroscope omega-Y: 0 [deg/s][older than 125 seconds]
	Magnetometer X: -20023 [nT][older than 125 seconds]
	Magnetometer Y: -26340 [nT][older than 125 seconds]
	Magnetometer Z: 12445 [nT][older than 125 seconds]
	COM temperature: -23.3 [C][0 seconds ago]
	STX temperature: 0.0 [C][INVALID value]
	RTCC temperature: 9.0 [C][1 seconds ago]
Packet - Telemetry 6
	Timestamp: 2024-01-26 10:54:24
	TID1 active: 1[older than 125 seconds]
	TID2 active: 1[32 seconds ago]
	TID1 temperature: -2.6 [C][older than 60 seconds]
	TID2 temperature: 0.0 [C][<=60 seconds ago]
	TID1 voltage: 3377 [mV][older than 60 seconds]
	TID2 voltage: 3330 [mV][<=60 seconds ago]
	TID1 measurement serial number: 16[older than 125 seconds]
	TID1 RadFET1: 7.295744 [mGray][older than 125 seconds]
	TID1 RadFET2: 7.111654 [mGray][older than 125 seconds]
	TID2 measurement serial number: 20[32 seconds ago]
	TID2 RadFET1: 4.196652 [mGray][32 seconds ago]
	TID2 RadFET2: 4.393518 [mGray][32 seconds ago]
	COM RX current: 14 [mA][<=20 seconds ago]
	COM idle current: 11 [mA][<=60 seconds ago]
	AIS1 buffered messages: 255[INVALID value]
	AIS2 buffered messages: 255[INVALID value]
	HAM repeater enabled: 0[INVALID value]
	ADCS programming enabled: 0[INVALID value]
	ADCS active: 0[INVALID value]
	ADCS exec: 0[INVALID value]
	ADCS erased: 0[INVALID value]
	ADCS valid code: 0[INVALID value]
	ADCS code CRC-16: 0xFFFF[INVALID value]
	ADCS SUN1 status: 0[INVALID value]
	ADCS SUN2 status: 0[INVALID value]
Packet - Beacon
	Timestamp: 2024-01-26 10:54:25
	Serial number -7: 1706095959	RSSI: 163[older than 125 seconds]
	Serial number -6: 1706101145	RSSI: 181[older than 125 seconds]
	Serial number -5: 1706101257	RSSI: 160[older than 125 seconds]
	Serial number -4: 1706101375	RSSI: 147[older than 125 seconds]
	Serial number -3: 1706101473	RSSI: 150[older than 125 seconds]
	Serial number -2: 1706101577	RSSI: 156[older than 125 seconds]
	Serial number -1: 1706266119	RSSI: 164[older than 125 seconds]
	Serial number -0: 1706266120	RSSI: 163[older than 125 seconds]
	COM telemetry TX max current: 112 [mA][<=20 seconds ago]
	COM telemetry TX min voltage: 3274 [mV][<=20 seconds ago]
	Active COM: COM-2[18 seconds ago]
	Energy management COM TX MCS: G012[0 seconds ago]
	Energy management COM TX power level: 15[0 seconds ago]
	Energy management COM cycle sleep time: 16 [sec][0 seconds ago]
	Energy management emergency mode: inactive[0 seconds ago]
	Message: Hello world! MRC-100 is alive!