Packet - Telemetry 4
	Timestamp: 2023-12-10 00:08:29
	ACCU1 active: 1[older than 125 seconds]
	ACCU2 active: 1[older than 125 seconds]
	ACCU1 current: 21 [mA][older than 60 seconds]
	ACCU2 current: 18 [mA][older than 60 seconds]
	ACCU1 Temperature X-: 2.2 [C][older than 60 seconds]
	ACCU1 Temperature Y-: 4.2 [C][older than 60 seconds]
	ACCU1 Temperature Y+: 1.4 [C][older than 60 seconds]
	ACCU1 Temperature Z-: 1.8 [C][older than 60 seconds]
	ACCU1 Temperature Z+: 0.1 [C][older than 60 seconds]
	ACCU1 Temperature PANEL: 1.3 [C][older than 60 seconds]
	ACCU1 Temperature REF: 91 [uA][older than 60 seconds]
	ACCU2 Temperature X+: 3.1 [C][older than 60 seconds]
	ACCU2 Temperature Y-: 3.7 [C][older than 60 seconds]
	ACCU2 Temperature Y+: 2.3 [C][older than 60 seconds]
	ACCU2 Temperature Z-: 0.6 [C][older than 60 seconds]
	ACCU2 Temperature Z+: 3.5 [C][older than 60 seconds]
	ACCU2 Temperature PANEL: 1.9 [C][older than 60 seconds]
	ACCU2 Temperature REF: 93 [uA][older than 60 seconds]
	GPS date: 2095-72-96[INVALID value]
	GPS time: 29:49:67.295[INVALID value]
	GPS Latitude: -0.000000 [deg][INVALID value]
	GPS Longitude: -0.000000 [deg][INVALID value]
	GPS Altitude: 4294967295 [m][INVALID value]
	GPS Velocity: 65535 [m/s][INVALID value]
	GPS Course: 6553.500 [deg][INVALID value]
	Gyroscope omega-P: 0 [deg/s][older than 125 seconds]
	Gyroscope omega-R: 0 [deg/s][older than 125 seconds]
	Gyroscope omega-Y: 0 [deg/s][older than 125 seconds]
	Magnetometer X: -20230 [nT][older than 125 seconds]
	Magnetometer Y: 20666 [nT][older than 125 seconds]
	Magnetometer Z: -28622 [nT][older than 125 seconds]
	COM temperature: 409.5 [C][0 seconds ago]
	STX temperature: 0.0 [C][INVALID value]
	RTCC temperature: 16.0 [C][<=5 seconds ago]
Packet - Telemetry 6
	Timestamp: 2023-12-10 00:08:31
	TID1 active: 1[older than 125 seconds]
	TID2 active: 1[older than 125 seconds]
	TID1 temperature: 13.4 [C][older than 60 seconds]
	TID2 temperature: 10.4 [C][older than 60 seconds]
	TID1 voltage: 2870 [mV][older than 60 seconds]
	TID2 voltage: 2769 [mV][older than 60 seconds]
	TID1 measurement serial number: 142[older than 125 seconds]
	TID1 RadFET1: 6.440618 [mGray][older than 125 seconds]
	TID1 RadFET2: 6.261737 [mGray][older than 125 seconds]
	TID2 measurement serial number: 150[older than 125 seconds]
	TID2 RadFET1: 3.480060 [mGray][older than 125 seconds]
	TID2 RadFET2: 3.613768 [mGray][older than 125 seconds]
	COM RX current: 13 [mA][older than 60 seconds]
	COM idle current: 6 [mA][<=60 seconds ago]
	AIS1 buffered messages: 255[INVALID value]
	AIS2 buffered messages: 255[INVALID value]
	HAM repeater enabled: 0[INVALID value]
	ADCS programming enabled: 0[INVALID value]
	ADCS active: 0[INVALID value]
	ADCS exec: 0[INVALID value]
	ADCS erased: 0[INVALID value]
	ADCS valid code: 0[INVALID value]
	ADCS code CRC-16: 0xFFFF[INVALID value]
	ADCS SUN1 status: 0[INVALID value]
	ADCS SUN2 status: 0[INVALID value]
Packet - Beacon
	Timestamp: 2023-12-10 00:08:33
	Serial number -7: 4294967295	RSSI: 255[INVALID value]
	Serial number -6: 4294967295	RSSI: 255[INVALID value]
	Serial number -5: 1702123081	RSSI: 158[older than 125 seconds]
	Serial number -4: 1702123312	RSSI: 157[older than 125 seconds]
	Serial number -3: 1702128706	RSSI: 145[older than 125 seconds]
	Serial number -2: 1702128707	RSSI: 146[older than 125 seconds]
	Serial number -1: 1702128884	RSSI: 158[older than 125 seconds]
	Serial number -0: 1702128889	RSSI: 156[older than 125 seconds]
	COM telemetry TX max current: 59 [mA][older than 60 seconds]
	COM telemetry TX min voltage: 2993 [mV][older than 60 seconds]
	Active COM: COM-2[24 seconds ago]
	Energy management COM TX MCS: G001[0 seconds ago]
	Energy management COM TX power level: 3[0 seconds ago]
	Energy management COM cycle sleep time: 480 [sec][0 seconds ago]
	Energy management emergency mode: ACTIVE[0 seconds ago]
	Message: Hello world! MRC-100 is alive!