Packet - Beacon Timestamp: 2023-10-23 11:13:30 Serial number -7: 1697808224 RSSI: 151[older than 125 seconds] Serial number -6: 1697808292 RSSI: 157[older than 125 seconds] Serial number -5: 1697808450 RSSI: 152[older than 125 seconds] Serial number -4: 1697808686 RSSI: 149[older than 125 seconds] Serial number -3: 1697888251 RSSI: 155[older than 125 seconds] Serial number -2: 1697888282 RSSI: 158[older than 125 seconds] Serial number -1: 1697973964 RSSI: 161[older than 125 seconds] Serial number -0: 1697974168 RSSI: 162[older than 125 seconds] COM telemetry TX max current: 79 [mA][<=20 seconds ago] COM telemetry TX min voltage: 3255 [mV][<=20 seconds ago] Active COM: COM-2[55 seconds ago] Energy management COM TX MCS: G012[0 seconds ago] Energy management COM TX power level: 14[0 seconds ago] Energy management COM cycle sleep time: 5 [sec][0 seconds ago] Energy management emergency mode: inactive[0 seconds ago] Message: Hello world! MRC-100 is alive! Packet - Telemetry 6 Timestamp: 2023-10-23 11:13:50 TID1 active: 1[older than 125 seconds] TID2 active: 1[older than 125 seconds] TID1 temperature: -2.1 [C][older than 60 seconds] TID2 temperature: -0.7 [C][older than 60 seconds] TID1 voltage: 3182 [mV][older than 60 seconds] TID2 voltage: 3158 [mV][older than 60 seconds] TID1 measurement serial number: 6[older than 125 seconds] TID1 RadFET1: 5.629514 [mGray][older than 125 seconds] TID1 RadFET2: 5.439568 [mGray][older than 125 seconds] TID2 measurement serial number: 6[older than 125 seconds] TID2 RadFET1: 2.628275 [mGray][older than 125 seconds] TID2 RadFET2: 2.826880 [mGray][older than 125 seconds] COM RX current: 14 [mA][<=10 seconds ago] COM idle current: 4 [mA][older than 60 seconds] AIS1 buffered messages: 255[INVALID value] AIS2 buffered messages: 255[INVALID value] HAM repeater enabled: 0[INVALID value] ADCS programming enabled: 0[INVALID value] ADCS active: 0[INVALID value] ADCS exec: 0[INVALID value] ADCS erased: 0[INVALID value] ADCS valid code: 0[INVALID value] ADCS code CRC-16: 0xFFFF[INVALID value] ADCS SUN1 status: 0[INVALID value] ADCS SUN2 status: 0[INVALID value] Packet - Beacon Timestamp: 2023-10-23 11:13:50 Serial number -7: 1697808224 RSSI: 151[older than 125 seconds] Serial number -6: 1697808292 RSSI: 157[older than 125 seconds] Serial number -5: 1697808450 RSSI: 152[older than 125 seconds] Serial number -4: 1697808686 RSSI: 149[older than 125 seconds] Serial number -3: 1697888251 RSSI: 155[older than 125 seconds] Serial number -2: 1697888282 RSSI: 158[older than 125 seconds] Serial number -1: 1697973964 RSSI: 161[older than 125 seconds] Serial number -0: 1697974168 RSSI: 162[older than 125 seconds] COM telemetry TX max current: 112 [mA][<=10 seconds ago] COM telemetry TX min voltage: 3314 [mV][<=10 seconds ago] Active COM: COM-2[75 seconds ago] Energy management COM TX MCS: G012[0 seconds ago] Energy management COM TX power level: 15[0 seconds ago] Energy management COM cycle sleep time: 3 [sec][0 seconds ago] Energy management emergency mode: inactive[0 seconds ago] Message: Hello world! MRC-100 is alive!